{"product_id":"haws-8317ctfp-config-std-sv-combination-eyewash-and-safety-shower","title":"Haws 8317CTFP Config STD-SV Combination Eyewash and Safety Shower, Freeze and Scald Protect Valves","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eHeat-traced stations solve the freezing problem, but in sun-baked yards and on sites that swing from frost to summer heat, water sitting in an exposed line can climb past a safe flushing temperature. The Haws 8317CTFP Config STD-SV adds a second line of protection for that case: alongside the standard freeze protection bleed valve, it carries an SP157A scald protection bleed valve that opens at 98°F (36.7°C) and closes again at 95°F (35°C), purging overheated water before it reaches the eyes or body.\u003c\/p\u003e\n\u003cp\u003eEverything else is the full 8317CTFP freeze-protected platform. A 120 VAC thermostatically controlled heat trace cable, 3\/4\" insulation and a UV-protected ABS jacket hold the unit operational down to -30°F (-34.4°C), and the thermal actuator freeze valve opens below 35°F (1.7°C) if power to the cable fails, closing at 42°F (5.6°C). The column is 1-1\/4\" Schedule 40 stainless steel with galvanized fittings on a powder-coated cast-iron floor flange, and a ball valve activated drench hose comes on the unit.\u003c\/p\u003e\n\u003cp\u003eThe AXION MSR eye\/face wash flushes at 4 GPM with inverted laminar streams that carry contaminants away from the nasal cavity, and the AXION MSR showerhead delivers an even 20 GPM drench. Electrical components are rated Class I, Division 2, Groups B, C and D at 1.25 amps max. It is CSA certified to ANSI\/ISEA Z358.1, built for year-round outdoor duty where both freezing and scalding are real risks. Plan for a heat traced and insulated supply line.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cp\u003e✓ \u003cstrong\u003eScald protection valve\u003c\/strong\u003e: SP157A bleed valve opens at 98°F and closes at 95°F to purge overheated water.\u003cbr\u003e✓ \u003cstrong\u003eFreeze protection valve\u003c\/strong\u003e: thermal actuator bleed valve opens below 35°F, closes at 42°F, as backup to the heat trace.\u003cbr\u003e✓ \u003cstrong\u003eAll-weather heat trace\u003c\/strong\u003e: 120V thermostatically controlled cable under 3\/4\" insulation and a UV-protected jacket, rated to -30°F.\u003cbr\u003e✓ \u003cstrong\u003eStainless steel column\u003c\/strong\u003e: 1-1\/4\" Schedule 40 stainless pipe stanchion with galvanized fittings.\u003cbr\u003e✓ \u003cstrong\u003eDrench hose on board\u003c\/strong\u003e: separate ball valve activated hose spray for spot flushing.\u003cbr\u003e✓ \u003cstrong\u003eAXION MSR eye\/face wash\u003c\/strong\u003e: inverted laminar flow at 4 GPM keeps contaminants away from the nose.\u003cbr\u003e✓ \u003cstrong\u003eEven 20 GPM drench\u003c\/strong\u003e: hydrodynamic AXION MSR showerhead spreads water across the whole pattern.\u003cbr\u003e✓ \u003cstrong\u003eClass I, Division 2 electrical\u003c\/strong\u003e: rated for Groups B, C and D hazardous locations.\u003cbr\u003e✓ \u003cstrong\u003eFactory tested\u003c\/strong\u003e: pre-built and pressure tested, with top or bottom supply and a weekly test card.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e8317CTFP Config STD-SV\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFreeze- and scald-protected combination drench shower and eye\/face wash with drench hose\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFloor-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePipe and Fittings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-1\/4\" Schedule 40 stainless steel pipe stanchion, galvanized fittings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFloor Flange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePowder-coated cast iron, 9\" (229 mm) diameter, 3 x 3\/8\" holes on 8\" (203 mm) bolt circle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEye\/Face Wash Head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAXION MSR, inverted directional laminar flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEye\/Face Wash Flow Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 GPM integral flow control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShowerhead\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAXION MSR hydrodynamic, green ABS plastic, 10-5\/8\" (269 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShower Flow Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 GPM self-regulating flow control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eValves\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChrome-plated brass ball valves, stainless steel ball and stem\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFreeze Protection Valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic thermal actuator bleed valve, opens below 35°F (1.7°C), closes at 42°F (5.6°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eScald Protection Valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSP157A thermal actuator bleed valve, opens at 98°F (36.7°C), closes at 95°F (35°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShower Activation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePull rod and handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrench Hose\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeparate ball valve activated hose spray\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeat Tracing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermostatically controlled electric heat traced cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/4\" (19 mm) insulation with UV-protected green ABS plastic jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFreeze Protection Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAmbient temperatures down to -30°F (-34.4°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 VAC, 1.25 amp max, 3\/4\" NPT junction box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHazardous Location Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass I, Division 2, Groups B, C and D, temperature code T6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-1\/4\" IPS, top or bottom supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95-1\/2\" (2426 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShowerhead Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85-1\/2\" (2172 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Inlet Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90-1\/2\" (2299 mm), top supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePull Handle Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e67-1\/4\" (1708 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEye\/Face Wash Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e41-3\/4\" (1060 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e43-1\/4\" (1098 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQPS-C-US certified, Type 4 (NEMA 4 equivalent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCSA certified to ANSI\/ISEA Z358.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 year from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eIncluded Components\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFreeze-protected combination shower and eye\/face wash assembly, pre-built and pressure tested\u003c\/li\u003e\n\u003cli\u003eSP157A scald protection bleed valve\u003c\/li\u003e\n\u003cli\u003eSP158B freeze protection bleed valve\u003c\/li\u003e\n\u003cli\u003e120V heat trace cable with thermostat and 3\/4\" NPT junction box\u003c\/li\u003e\n\u003cli\u003eAXION MSR eye\/face wash head and AXION MSR green ABS drench showerhead\u003c\/li\u003e\n\u003cli\u003eDrench hose with activation valve assembly\u003c\/li\u003e\n\u003cli\u003ePull rod and handle (field assembled)\u003c\/li\u003e\n\u003cli\u003eTest tag and universal shower\/eyewash sign with mounting screws\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCertifications \u0026amp; Compliance\u003c\/h2\u003e\n\u003cp\u003e✅ CSA certified to ANSI\/ISEA Z358.1\u003cbr\u003e✅ Rated Class I, Division 2, Groups B, C and D\u003cbr\u003e✅ QPS-C-US certified, Type 4 (NEMA 4 equivalent)\u003cbr\u003e✅ Helps meet OSHA requirements for emergency eyewash and shower facilities\u003cbr\u003e⚠️ California Proposition 65: this product contains a chemical known to the State of California to cause cancer and\/or birth defects or other reproductive harm.\u003c\/p\u003e\n\u003ch2\u003eWarranty \u0026amp; Return Policy\u003c\/h2\u003e\n\u003cp\u003eHaws covers this unit against defects in material and workmanship for 1 year from the date of shipment. Full terms in the \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0619\/5085\/3222\/files\/fd-filter-6423-haws-limited-warranty.pdf?v=1783963147\" target=\"_blank\" rel=\"noopener\"\u003eHaws Limited Warranty\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0619\/5085\/3222\/files\/haws-8317ctfp-config-std-sv-spec-sheet.pdf?v=1793906830\" target=\"_blank\" rel=\"noopener\"\u003eSpec Sheet - Haws 8317CTFP Config STD-SV (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0619\/5085\/3222\/files\/haws-8317ctfp-config-std-sv-installation-operation-maintenance-manual.pdf?v=1793906834\" target=\"_blank\" rel=\"noopener\"\u003eInstallation, Operation \u0026amp; Maintenance Manual - Haws 8317CTFP Config STD-SV (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0619\/5085\/3222\/files\/haws-8317ctfp-config-std-sv-installation-drawing.pdf?v=1793906838\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Drawing - Haws 8317CTFP Config STD-SV (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0619\/5085\/3222\/files\/haws-8317ctfp-config-std-sv-parts-breakdown.pdf?v=1793906872\" target=\"_blank\" rel=\"noopener\"\u003eParts Breakdown - Haws 8317CTFP Config STD-SV (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0619\/5085\/3222\/files\/fd-filter-6423-haws-limited-warranty.pdf?v=1783963147\" target=\"_blank\" rel=\"noopener\"\u003eHaws Limited Warranty (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Haws","offers":[{"title":"Default Title","offer_id":67929833799782,"sku":"8317CTFP Config STD-SV","price":5207.76,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0619\/5085\/3222\/files\/haws-8317ctfp-config-std-sv-emergency-shower-eyewash-station.png?v=1793906878","url":"https:\/\/thefountaindirect.com\/products\/haws-8317ctfp-config-std-sv-combination-eyewash-and-safety-shower","provider":"The Fountain Direct ","version":"1.0","type":"link"}